4U2Q
Full-length AMPA subtype ionotropic glutamate receptor GluA2 in complex with partial agonist kainate
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.2 |
| Synchrotron site | ALS |
| Beamline | 5.0.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2013-01-12 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 104.940, 148.650, 337.060 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 83.084 - 3.525 |
| R-factor | 0.2709 |
| Rwork | 0.269 |
| R-free | 0.31750 |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.881 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.8.2_1309)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 83.084 |
| High resolution limit [Å] | 3.500 |
| Number of reflections | 39983 |
| <I/σ(I)> | 6.45 |
| Completeness [%] | 80.8 |
| Redundancy | 4.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 277.15 | 0.1 M MES, 4.8-5.3% PEG6000, 3.5% TMAO, 6 mM taurine |