Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-ID |
| Synchrotron site | APS |
| Beamline | 19-ID |
| Detector technology | CCD |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.9793 |
| Spacegroup name | P 62 2 2 |
| Unit cell lengths | 180.154, 180.154, 77.548 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 46.940 - 2.600 |
| R-factor | 0.2037 |
| Rwork | 0.202 |
| R-free | 0.24840 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2x69 |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.744 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((phenix.refine: 1.9_1692)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.600 |
| Number of reflections | 21934 |
| Completeness [%] | 99.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | 0.1 M Bis-Tris, pH 5.5, 2 M ammonium sulfate, VAPOR DIFFUSION, HANGING DROP, temperature 298K |