4QZV
Bat-derived coronavirus HKU4 uses MERS-CoV receptor human CD26 for cell entry
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-10-21 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.9795 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 78.801, 203.166, 207.753 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 46.301 - 2.592 |
R-factor | 0.1912 |
Rwork | 0.190 |
R-free | 0.22360 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.944 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.8.4_1496)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.690 |
High resolution limit [Å] | 2.592 | 2.600 |
Number of reflections | 102311 | |
Completeness [%] | 98.0 | 95.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 277 | 0.1M sodium citrate, pH 5.5, 15% PEG 6000, VAPOR DIFFUSION, SITTING DROP, temperature 277K |