Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4QH8

LC8 - Ana2 (237-246) Complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2013-10-19
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.07426
Spacegroup nameP 1
Unit cell lengths36.627, 44.802, 85.895
Unit cell angles99.33, 103.04, 91.79
Refinement procedure
Resolution35.594 - 1.900
R-factor0.188
Rwork0.185
R-free0.23580
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2pg1
RMSD bond length0.008
RMSD bond angle1.051
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX ((phenix.refine: 1.8.1_1168))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.970
High resolution limit [Å]1.9001.900
Number of reflections36096
<I/σ(I)>19.57
Completeness [%]87.547.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP4.6293.150.19M ammonium acetate, 0.1M sodium acetate, 0.1% beta-mercaptoethanol, and 27% PEG 4000, pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 293.15K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon