4PQN
ITK kinase domain with compound GNE-9822
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 110 |
Detector technology | CCD |
Collection date | 2011-12-02 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9795 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 120.180, 39.030, 50.680 |
Unit cell angles | 90.00, 93.07, 90.00 |
Refinement procedure
Resolution | 50.600 - 1.710 |
R-factor | 0.16125 |
Rwork | 0.159 |
R-free | 0.20164 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1sm2 |
RMSD bond length | 0.019 |
RMSD bond angle | 1.983 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0049) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.600 |
High resolution limit [Å] | 1.710 |
Rmerge | 0.073 |
Number of reflections | 25457 |
<I/σ(I)> | 13.3 |
Completeness [%] | 99.1 |
Redundancy | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 277 | PEG6000, NaCl, VAPOR DIFFUSION, SITTING DROP, temperature 277K |