4PKQ
Anthrax toxin lethal factor with bound zinc
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2013-12-15 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 56.897, 74.544, 139.461 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 52.681 - 2.200 |
| R-factor | 0.1778 |
| Rwork | 0.176 |
| R-free | 0.21710 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.721 |
| Data reduction software | XDS (2.5.1) |
| Data scaling software | SCALA |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 139.461 |
| High resolution limit [Å] | 2.200 |
| Rmerge | 0.068 |
| Number of reflections | 30912 |
| <I/σ(I)> | 20.8 |
| Completeness [%] | 100.0 |
| Redundancy | 6.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 286 | 11-16% PEG 8K, 50 mM Bis-Tris, 100 mM magnesium acetate |