4P7F
Mouse apo-COMT
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X10SA |
| Synchrotron site | SLS |
| Beamline | X10SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2010-05-07 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.9998 |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 123.822, 123.822, 88.369 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 40.800 - 1.370 |
| R-factor | 0.1258 |
| Rwork | 0.123 |
| R-free | 0.17080 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.212 |
| Refinement software | PHENIX ((phenix.refine: 1.9_1692)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.800 | 1.420 |
| High resolution limit [Å] | 1.370 | 1.370 |
| Rmerge | 0.069 | 0.024 |
| Number of reflections | 54274 | |
| <I/σ(I)> | 14.8069 | 0.864 |
| Completeness [%] | 99.7 | 99.1 |
| Redundancy | 10 | 9.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 |