4OWI
peptide structure
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2013-03-01 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.97935 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 30.480, 29.390, 32.700 |
| Unit cell angles | 90.00, 98.25, 90.00 |
Refinement procedure
| Resolution | 30.165 - 1.202 |
| R-factor | 0.1632 |
| Rwork | 0.162 |
| R-free | 0.19470 |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.157 |
| Refinement software | PHENIX ((phenix.refine: 1.7.1_743)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 30.165 |
| High resolution limit [Å] | 1.200 |
| Number of reflections | 17562 |
| <I/σ(I)> | 59.73 |
| Completeness [%] | 97.5 |
| Redundancy | 6.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 291.15 | ethanol |