4OHE
LEOPARD Syndrome-Associated SHP2/G464A mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-03-22 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97934 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 55.485, 204.889, 44.492 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 37.636 - 2.506 |
R-factor | 0.1903 |
Rwork | 0.187 |
R-free | 0.25610 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4dgp |
RMSD bond length | 0.008 |
RMSD bond angle | 1.068 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | MOLREP |
Refinement software | PHENIX ((phenix.refine: 1.7.3_928)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.540 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.161 | 0.682 |
Number of reflections | 103779 | |
<I/σ(I)> | 14.87 | 1.857 |
Completeness [%] | 99.7 | 99.9 |
Redundancy | 5.8 | 5.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 293 | 20% PEG3350, 300 mM LiCl, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K |