Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4OHE

LEOPARD Syndrome-Associated SHP2/G464A mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyCCD
Collection date2012-03-22
DetectorADSC QUANTUM 315r
Wavelength(s)0.97934
Spacegroup nameP 21 21 2
Unit cell lengths55.485, 204.889, 44.492
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution37.636 - 2.506
R-factor0.1903
Rwork0.187
R-free0.25610
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4dgp
RMSD bond length0.008
RMSD bond angle1.068
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwareMOLREP
Refinement softwarePHENIX ((phenix.refine: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.540
High resolution limit [Å]2.5002.500
Rmerge0.1610.682
Number of reflections103779
<I/σ(I)>14.871.857
Completeness [%]99.799.9
Redundancy5.85.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.829320% PEG3350, 300 mM LiCl, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon