Zymogen HGF-beta/MET with Zymogen Activator Peptide ZAP.14

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-F
Synchrotron siteAPS
Beamline21-ID-F
Temperature [K]110
Detector technologyCCD
Collection date2011-11-04
DetectorRAYONIX MX-225
Wavelength(s)0.9787
Spacegroup nameP 21 21 21
Unit cell lengths59.789, 121.467, 137.657
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.540 - 2.990
R-factor0.2334
Rwork0.232
R-free0.27580
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1shy
RMSD bond length0.009
RMSD bond angle1.080
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.2)
Data quality characteristics
 Overall
Low resolution limit [Å]45.540
High resolution limit [Å]2.990
Number of reflections20853
<I/σ(I)>15
Completeness [%]99.7
Redundancy6.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.5293PEG6000, 800 mM NaCl, 400 mM trimethylammonium oxide, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K