4NJ7
PB1 Domain of AtARF7 - SeMet Derivative
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-ID |
| Synchrotron site | APS |
| Beamline | 19-ID |
| Temperature [K] | 77 |
| Detector technology | CCD |
| Collection date | 2013-08-01 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.979 |
| Spacegroup name | H 3 |
| Unit cell lengths | 150.936, 150.936, 184.236 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 47.600 - 3.000 |
| R-factor | 0.261 |
| Rwork | 0.257 |
| R-free | 0.30400 |
| Structure solution method | SAD |
| RMSD bond length | 0.025 |
| RMSD bond angle | 2.048 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((phenix.refine: 1.7.3_928)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.634 | 3.180 |
| High resolution limit [Å] | 3.000 | 3.000 |
| Number of reflections | 28097 | |
| Completeness [%] | 100.0 | 100 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 277 | 20% PEG-3350, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |