4NE3
Human MHF1-MHF2 complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 1 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 61.969, 52.945, 60.283 |
| Unit cell angles | 90.00, 114.91, 90.00 |
Refinement procedure
| Resolution | 28.102 - 1.801 |
| R-factor | 0.2324 |
| Rwork | 0.231 |
| R-free | 0.25200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.928 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.6.4_486) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 28.102 |
| High resolution limit [Å] | 1.801 |
| Number of reflections | 16358 |
| Completeness [%] | 99.0 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |