4KL1

HCN4 CNBD in complex with cGMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2010-01-29
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97240
Spacegroup nameP 21 21 21
Unit cell lengths97.100, 99.030, 109.570
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution58.620 - 2.700
R-factor0.21403
Rwork0.210
R-free0.27226
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3u11
RMSD bond length0.018
RMSD bond angle1.862
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASES
Refinement softwareREFMAC (5.5.0110)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]58.6202.850
High resolution limit [Å]2.7002.700
Rmerge0.1000.450
Number of reflections29735
<I/σ(I)>18.14.3
Completeness [%]100.0100
Redundancy7.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP529810-15% PEG3350, 200 mM sodium acetate buffer, 200 mM ammonium phosphate, 5-50mM cGMP, pH 5.0, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K

219869