4KF8
Nup188(aa1445-1827) from Myceliophthora thermophila
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-03-03 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 0.9792 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 64.298, 66.651, 162.262 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 81.131 - 3.000 |
R-factor | 0.2769 |
Rwork | 0.275 |
R-free | 0.29420 |
Structure solution method | SAD |
RMSD bond length | 0.003 |
RMSD bond angle | 0.769 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHELXS |
Refinement software | PHENIX |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 81.131 | 3.110 |
High resolution limit [Å] | 3.000 | 3.000 |
Rmerge | 0.027 | 0.561 |
Number of reflections | 14539 | |
<I/σ(I)> | 21.4 | 4.8 |
Completeness [%] | 99.0 | 99.7 |
Redundancy | 3.5 | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 290 | 18-23% w/v PEG3350, 150 mM tri-ammonium citrate, 1 mM DTT, VAPOR DIFFUSION, HANGING DROP, temperature 290K |