BRDT in complex with Dinaciclib

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2013-04-13
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths64.720, 29.950, 71.380
Unit cell angles90.00, 94.12, 90.00
Refinement procedure
Resolution19.811 - 2.000
R-factor0.2114
Rwork0.209
R-free0.25300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4flp
RMSD bond length0.008
RMSD bond angle1.189
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.7.3_928))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.100
High resolution limit [Å]2.0002.000
Rmerge0.1270.624
Number of reflections18535
<I/σ(I)>7.73.3
Completeness [%]97.098.1
Redundancy3.43.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529125mM HEPES PH 7.5, 0.1M NaCl, 1mM DTT 0.1M KSCN, 7% PEG3350, 5% ETGLY, VAPOR DIFFUSION, SITTING DROP, temperature 291K