4J4Y

Triple mutant GraVN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]100
Detector technologyCCD
Collection date2011-11-26
DetectorADSC QUANTUM 315
Wavelength(s)0.98
Spacegroup nameP 1
Unit cell lengths54.160, 76.798, 77.156
Unit cell angles82.79, 69.51, 69.36
Refinement procedure
Resolution28.810 - 2.450
R-factor0.21412
Rwork0.210
R-free0.29102
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4j4r
RMSD bond length0.012
RMSD bond angle1.639
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASES
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]28.8302.590
High resolution limit [Å]2.4502.500
Number of reflections35932
Completeness [%]95.291.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP62980.1M Ca(OAc)2, 12%(w/v) PEG3350, 0.04M citric acid, 0.06M Bis-tris, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219869