Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4J4U

Pentamer SFTSVN

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U
Synchrotron siteSSRF
BeamlineBL17U
Temperature [K]100
Detector technologyCCD
Collection date2011-11-26
DetectorADSC QUANTUM 315
Wavelength(s)0.98
Spacegroup nameC 1 2 1
Unit cell lengths111.188, 155.573, 97.656
Unit cell angles90.00, 107.52, 90.00
Refinement procedure
Resolution43.808 - 2.803
R-factor0.1998
Rwork0.195
R-free0.27900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4j4r
RMSD bond length0.010
RMSD bond angle1.236
Refinement softwarePHENIX ((phenix.refine: 1.8.1_1168))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.8102.900
High resolution limit [Å]2.8002.800
Number of reflections38804
Completeness [%]92.592.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

219869

PDB entries from 2024-05-15