4J4U
Pentamer SFTSVN
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-11-26 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.98 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 111.188, 155.573, 97.656 |
Unit cell angles | 90.00, 107.52, 90.00 |
Refinement procedure
Resolution | 43.808 - 2.803 |
R-factor | 0.1998 |
Rwork | 0.195 |
R-free | 0.27900 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4j4r |
RMSD bond length | 0.010 |
RMSD bond angle | 1.236 |
Refinement software | PHENIX ((phenix.refine: 1.8.1_1168)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 43.810 | 2.900 |
High resolution limit [Å] | 2.800 | 2.800 |
Number of reflections | 38804 | |
Completeness [%] | 92.5 | 92.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |