4HZL
Neutralizing antibody mAb#8 in complex with the Epitope II of HCV E2 envelope protein
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | NSLS BEAMLINE X29A |
| Synchrotron site | NSLS |
| Beamline | X29A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-06-01 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 1.0 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 137.252, 137.252, 140.490 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 50.000 - 2.850 |
| R-factor | 0.22387 |
| Rwork | 0.221 |
| R-free | 0.27715 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1zea |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.811 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 3.000 |
| High resolution limit [Å] | 2.850 | 2.850 |
| Rmerge | 0.135 | 0.372 |
| Number of reflections | 30296 | |
| <I/σ(I)> | 10.8 | 3.8 |
| Completeness [%] | 99.8 | 53.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8 | 294 | 0.1 M Tris-HCl buffer (pH 8.0) 16% (wt/vol) polyethylene glycol 10,000, 0.2 M ammonium acetate, VAPOR DIFFUSION, HANGING DROP, temperature 294K |