Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | EMBL/DESY, HAMBURG BEAMLINE BW7B |
| Synchrotron site | EMBL/DESY, HAMBURG |
| Beamline | BW7B |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 1998-07-01 |
| Detector | MAR scanner 345 mm plate |
| Wavelength(s) | 0.8420 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 78.778, 94.853, 162.016 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 22.758 - 2.300 |
| R-factor | 0.1668 |
| Rwork | 0.163 |
| R-free | 0.20300 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3t36 |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.185 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((phenix.refine: 1.8_1069)) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 23.000 |
| High resolution limit [Å] | 2.300 |
| Number of reflections | 54621 |
| <I/σ(I)> | 13.1 |
| Completeness [%] | 98.2 |
| Redundancy | 4.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 0.1 M lithium sulfate, 15% PEG8000, 20 mM HEPES, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |