4HFI
The GLIC pentameric Ligand-Gated Ion Channel at 2.4 A resolution
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SOLEIL BEAMLINE PROXIMA 1 |
| Synchrotron site | SOLEIL |
| Beamline | PROXIMA 1 |
| Temperature [K] | 200 |
| Detector technology | CCD |
| Collection date | 2010-12-22 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 0.9193 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 181.890, 133.200, 160.200 |
| Unit cell angles | 90.00, 102.74, 90.00 |
Refinement procedure
| Resolution | 54.050 - 2.400 |
| R-factor | 0.2054 |
| Rwork | 0.205 |
| R-free | 0.21610 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.000 |
| Data reduction software | XDS |
| Data scaling software | SCALA |
| Refinement software | BUSTER (2.11.2) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 70.700 | 70.700 | 2.530 |
| High resolution limit [Å] | 2.400 | 7.590 | 2.400 |
| Rmerge | 0.084 | 0.037 | 0.672 |
| <I/σ(I)> | 11.5 | 47.4 | 1.7 |
| Completeness [%] | 98.9 | 94.9 | 95.3 |
| Redundancy | 4.8 | 5.1 | 4.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4 | 291 | 12-15% PEG4K, 0.1M Na Acetate pH4, 0.4M NaSCN, VAPOR DIFFUSION, HANGING DROP, temperature 291K |