4GUV
TetX derivatized with Xenon
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | RAYONIX MX-225 |
Wavelength(s) | 1.5 |
Spacegroup name | P 1 |
Unit cell lengths | 68.710, 80.140, 87.500 |
Unit cell angles | 111.04, 90.06, 93.29 |
Refinement procedure
Resolution | 47.270 - 2.730 |
R-factor | 0.18332 |
Rwork | 0.181 |
R-free | 0.22105 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2xdo |
RMSD bond length | 0.013 |
RMSD bond angle | 1.683 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.6.0116) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.800 |
High resolution limit [Å] | 2.730 | 2.730 |
Rmerge | 0.140 | 0.890 |
Number of reflections | 41035 | |
<I/σ(I)> | 11.79 | 1.74 |
Redundancy | 3.43 | 1.83 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 293K |