4GT9

T. Maritima FDTS with FAD, dUMP and Folate.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL9-2
Synchrotron siteSSRL
BeamlineBL9-2
Temperature [K]100
Detector technologyCCD
Collection date2011-03-11
DetectorMARMOSAIC 325 mm CCD
Wavelength(s)0.9809
Spacegroup nameI 41 2 2
Unit cell lengths110.320, 110.320, 120.570
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution27.580 - 1.390
R-factor0.15295
Rwork0.152
R-free0.16416
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1o26
RMSD bond length0.015
RMSD bond angle1.756
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0110)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.0001.430
High resolution limit [Å]1.3901.390
Rmerge0.0430.876
Number of reflections74209
<I/σ(I)>27.72.7
Completeness [%]99.699.9
Redundancy8.48.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.582953-6% PEG 4K (w/v), 200mM NaCl, 100 mM Na/K phosphate (pH 6.58), VAPOR DIFFUSION, HANGING DROP, temperature 295K

219869