4GG8
Immune Receptor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX1 |
Synchrotron site | Australian Synchrotron |
Beamline | MX1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-05-03 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 0.956591 |
Spacegroup name | P 3 |
Unit cell lengths | 124.562, 124.562, 61.098 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.990 - 3.200 |
R-factor | 0.265 |
Rwork | 0.261 |
R-free | 0.30800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4gg6 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.049 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.5.0088) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.310 |
High resolution limit [Å] | 3.200 | 3.200 |
Rmerge | 0.072 | 0.389 |
Number of reflections | 15462 | |
<I/σ(I)> | 14.6 | 2.2 |
Completeness [%] | 87.2 | 89.7 |
Redundancy | 2 | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 294 | 3.8M SODIUM FORMATE, 0.1M TRIS PH 7.5, 5% PEG 4000, VAPOR DIFFUSION, HANGING DROP, temperature 294K |