4GFU
PTPN18 in complex with HER2-pY1248 phosphor-peptides
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Temperature [K] | 100 |
| Detector technology | DIFFRACTOMETER |
| Collection date | 2011-08-07 |
| Detector | SYNTEX |
| Wavelength(s) | 0.98 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 44.032, 71.766, 57.161 |
| Unit cell angles | 90.00, 99.52, 90.00 |
Refinement procedure
| Resolution | 33.260 - 2.000 |
| R-factor | 0.1915 |
| Rwork | 0.189 |
| R-free | 0.23190 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2oc3 |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.016 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.6.2_432)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 80.000 | 2.091 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Rmerge | 0.075 | |
| Number of reflections | 22674 | |
| Completeness [%] | 95.3 | 98 |
| Redundancy | 3.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 295.15 | 18%-22% PEG4K, 6% Jeffamine M 600, 0.1 M HEPES, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 295.15K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.8 | 295.15 | 18%-22% PEG4K, 6% Jeffamine M 600, 0.1 M HEPES, pH 6.8, VAPOR DIFFUSION, HANGING DROP, temperature 295.15K |