4G8W
Rat Heme Oxygenase-1 in complex with Heme and O2 with 13 hr illumination: Laser on
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 14-BM-C |
| Synchrotron site | APS |
| Beamline | 14-BM-C |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2012-04-25 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.979 |
| Spacegroup name | P 32 2 1 |
| Unit cell lengths | 65.300, 65.300, 121.465 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 28.760 - 2.400 |
| R-factor | 0.16868 |
| Rwork | 0.166 |
| R-free | 0.22833 |
| Structure solution method | FOURIER SYNTHESIS |
| Starting model (for MR) | 4g8u |
| RMSD bond length | 0.016 |
| RMSD bond angle | 2.223 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | REFMAC (5.6.0117) |
| Refinement software | REFMAC (5.6.0117) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.440 |
| High resolution limit [Å] | 2.400 | 2.400 |
| Number of reflections | 12112 | |
| <I/σ(I)> | 9.4 | |
| Completeness [%] | 98.7 | 99.2 |
| Redundancy | 3.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 4M sodium formate, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |