4EAX
Mouse NGF in complex with Lyso-PS
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-06-08 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.009 |
Spacegroup name | H 3 |
Unit cell lengths | 96.529, 96.529, 163.780 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 40.500 - 2.300 |
R-factor | 0.2208 |
Rwork | 0.219 |
R-free | 0.25930 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1btg |
RMSD bond length | 0.010 |
RMSD bond angle | 1.234 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | PHENIX ((phenix.refine: 1.6_289)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.500 | 2.380 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.493 | |
Number of reflections | 24969 | |
<I/σ(I)> | 2.7 | |
Completeness [%] | 98.7 | 89.3 |
Redundancy | 7.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 289 | 0.1M Imidazole, 1.0M Sodium Acetate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 289K |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 289 | 0.1M Imidazole, 1.0M Sodium Acetate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 289K |