4EAX
Mouse NGF in complex with Lyso-PS
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U |
| Synchrotron site | SSRF |
| Beamline | BL17U |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-06-08 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.009 |
| Spacegroup name | H 3 |
| Unit cell lengths | 96.529, 96.529, 163.780 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 40.500 - 2.300 |
| R-factor | 0.2208 |
| Rwork | 0.219 |
| R-free | 0.25930 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1btg |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.234 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((phenix.refine: 1.6_289)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.500 | 2.380 |
| High resolution limit [Å] | 2.300 | 2.300 |
| Rmerge | 0.493 | |
| Number of reflections | 24969 | |
| <I/σ(I)> | 2.7 | |
| Completeness [%] | 98.7 | 89.3 |
| Redundancy | 7.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 289 | 0.1M Imidazole, 1.0M Sodium Acetate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 289K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 289 | 0.1M Imidazole, 1.0M Sodium Acetate, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 289K |