4E6A
p38a-PIA23 complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-2 |
Synchrotron site | ESRF |
Beamline | ID23-2 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2009-12-09 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 0.873 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 68.368, 74.619, 74.405 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 52.700 - 2.090 |
R-factor | 0.22359 |
Rwork | 0.221 |
R-free | 0.27314 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.017 |
RMSD bond angle | 1.511 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 52.700 |
High resolution limit [Å] | 2.090 |
Number of reflections | 22808 |
<I/σ(I)> | 28.9 |
Completeness [%] | 99.1 |
Redundancy | 5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 277 | 13%-17% (w/v) PEG 3350, 0.1M Hepes pH 6.5-7.25, 0.2M KF, VAPOR DIFFUSION, SITTING DROP, temperature 277K |