4E5N
Thermostable phosphite dehydrogenase in complex with NAD
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 21-ID-D |
| Synchrotron site | APS |
| Beamline | 21-ID-D |
| Detector technology | CCD |
| Detector | MARMOSAIC 300 mm CCD |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 90.710, 113.540, 130.190 |
| Unit cell angles | 90.00, 100.16, 90.00 |
Refinement procedure
| Resolution | 25.000 - 1.700 |
| R-factor | 0.212 |
| Rwork | 0.210 |
| R-free | 0.24698 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | Thermostable phosphite dehydrogenase E175A variant |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.159 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 80.000 | 1.800 |
| High resolution limit [Å] | 1.700 | 1.700 |
| Rmerge | 0.054 | 0.436 |
| Number of reflections | 270433 | |
| <I/σ(I)> | 19.2 | 3 |
| Completeness [%] | 95.0 | 74.1 |
| Redundancy | 6 | 3.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 285 | 25-30% PEG 3350, 100 mM KCl, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 285K |