4CZI
C. crescentus MreB, single filament, empty
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Detector | DECTRIS PILATUS |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 51.951, 69.238, 52.183 |
Unit cell angles | 90.00, 99.56, 90.00 |
Refinement procedure
Resolution | 41.182 - 1.800 |
R-factor | 0.1858 |
Rwork | 0.184 |
R-free | 0.21690 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1jce |
RMSD bond length | 0.011 |
RMSD bond angle | 1.298 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.900 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.060 | 0.350 |
Number of reflections | 33485 | |
<I/σ(I)> | 15.2 | 4.2 |
Completeness [%] | 99.3 | 99.1 |
Redundancy | 3.7 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |