Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4CZI

C. crescentus MreB, single filament, empty

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
DetectorDECTRIS PILATUS
Spacegroup nameP 1 21 1
Unit cell lengths51.951, 69.238, 52.183
Unit cell angles90.00, 99.56, 90.00
Refinement procedure
Resolution41.182 - 1.800
R-factor0.1858
Rwork0.184
R-free0.21690
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1jce
RMSD bond length0.011
RMSD bond angle1.298
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.900
High resolution limit [Å]1.8001.800
Rmerge0.0600.350
Number of reflections33485
<I/σ(I)>15.24.2
Completeness [%]99.399.1
Redundancy3.73.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

220113

PDB entries from 2024-05-22

PDB statisticsPDBj update infoContact PDBjnumon