Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

4C46

ANDREI-N-LVPAS fused to GCN4 adaptors

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2013-08-25
DetectorDECTRIS PILATUS 6M
Spacegroup nameP 1 21 1
Unit cell lengths42.000, 41.600, 64.140
Unit cell angles90.00, 95.48, 90.00
Refinement procedure
Resolution36.640 - 1.950
R-factor0.23962
Rwork0.238
R-free0.27543
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1gcm
RMSD bond length0.016
RMSD bond angle1.717
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwareREFMAC (5.7.0029)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]36.6002.070
High resolution limit [Å]1.9501.950
Rmerge0.0600.580
Number of reflections16104
<I/σ(I)>11.31.94
Completeness [%]98.797.5
Redundancy3.283.33
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4SITTING DROP, PROTEIN SOLUTION 50 MM NACL AND 50 MM SODIUM ACETATE PH 4.0, RESERVOUR SOLUTION 0.1 M HEPES PH 7.5 1.75 M SODIUM BROMIDE

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon