Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

4C3D

HRSV M2-1, P422 crystal form

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
Collection date2013-01-31
DetectorDECTRIS PILATUS 6M
Spacegroup nameP 4 2 2
Unit cell lengths102.275, 102.275, 90.993
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.740 - 2.520
R-factor0.21351
Rwork0.211
R-free0.26323
Structure solution methodSAD
Starting model (for MR)NONE
RMSD bond length0.013
RMSD bond angle1.460
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwareAutoSol
Refinement softwareREFMAC (5.7.0032)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.7402.610
High resolution limit [Å]2.5202.520
Rmerge0.1000.650
Number of reflections16695
<I/σ(I)>14.83.8
Completeness [%]98.991.2
Redundancy306
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
11030 % (V/V) PEG 400, 0.01 M CDCL2, 0.1 M CAPS PH 10

229681

PDB entries from 2025-01-08

PDB statisticsPDBj update infoContact PDBjnumon