4BEZ
Night blindness causing G90D rhodopsin in the active conformation
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X06SA |
| Synchrotron site | SLS |
| Beamline | X06SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Detector | DECTRIS PILATUS 6M |
| Spacegroup name | H 3 2 |
| Unit cell lengths | 242.440, 242.440, 110.360 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 40.000 - 3.300 |
| R-factor | 0.2299 |
| Rwork | 0.229 |
| R-free | 0.24430 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4a4m |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.601 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER (MR) |
| Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.000 | 3.470 |
| High resolution limit [Å] | 3.300 | 3.300 |
| Rmerge | 0.310 | |
| Number of reflections | 18833 | |
| <I/σ(I)> | 9 | 1.43 |
| Completeness [%] | 99.4 | 97.4 |
| Redundancy | 20.2 | 20.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |