4AKI
Dynein Motor Domain - LuAc derivative
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-08-06 |
Detector | ADSC CCD |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 175.769, 118.186, 202.679 |
Unit cell angles | 90.00, 90.91, 90.00 |
Refinement procedure
Resolution | 49.140 - 3.700 |
R-factor | 0.2335 |
Rwork | 0.231 |
R-free | 0.28903 |
Structure solution method | SAD |
Starting model (for MR) | NONE |
RMSD bond length | 0.010 |
RMSD bond angle | 1.511 |
Data reduction software | MOSFLM |
Data scaling software | Aimless |
Refinement software | REFMAC (5.7.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.130 | 3.770 |
High resolution limit [Å] | 3.700 | 3.700 |
Rmerge | 0.150 | |
Number of reflections | 88918 | |
<I/σ(I)> | 9.4 | 2 |
Completeness [%] | 99.9 | 99.7 |
Redundancy | 9.9 | 8.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |