Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ELETTRA BEAMLINE 11.2C |
| Synchrotron site | ELETTRA |
| Beamline | 11.2C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2025-01-15 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1.0001 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 45.190, 45.190, 105.109 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.260 - 1.660 |
| R-factor | 0.2087 |
| Rwork | 0.207 |
| R-free | 0.23210 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.929 |
| Data reduction software | MOSFLM |
| Data scaling software | Aimless |
| Phasing software | MOLREP |
| Refinement software | REFMAC (v 5.8) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 41.520 | 1.660 |
| High resolution limit [Å] | 1.630 | 1.630 |
| Rmeas | 0.129 | 2.760 |
| Number of reflections | 14226 | 689 |
| <I/σ(I)> | 12.5 | |
| Completeness [%] | 99.5 | |
| Redundancy | 22.4 | |
| CC(1/2) | 0.999 | 0.730 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 0.2 M magnesium formate pH 5.3-5.6 and PEG 3350 16-26%, 1mM DM ligand |