3ZNM
H5 Haemagglutinin in Complex with Sialyl-Lewis X
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-04-23 |
Detector | DECTRIS PILATUS 2M |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 175.560, 101.360, 161.200 |
Unit cell angles | 90.00, 111.29, 90.00 |
Refinement procedure
Resolution | 37.150 - 2.400 |
R-factor | 0.2387 |
Rwork | 0.238 |
R-free | 0.25632 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2ibx |
RMSD bond length | 0.005 |
RMSD bond angle | 0.997 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0032) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 150.760 |
High resolution limit [Å] | 2.400 |
Rmerge | 0.080 |
Number of reflections | 77719 |
<I/σ(I)> | 8.2 |
Completeness [%] | 75.6 |
Redundancy | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 0.1 M HEPES, PH 7.0, 0.05 M MGCL2, 28 - 30 % PEG 550 MME |