3WGN

STAPHYLOCOCCUS AUREUS FTSZ bound with GTP-gamma-S

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE BL-17A
Synchrotron sitePhoton Factory
BeamlineBL-17A
Temperature [K]100
Detector technologyCCD
Collection date2011-12-04
DetectorADSC QUANTUM 315r
Wavelength(s)0.9800
Spacegroup nameP 1
Unit cell lengths44.270, 44.170, 73.280
Unit cell angles82.84, 82.81, 82.34
Refinement procedure
Resolution43.511 - 2.606
R-factor0.2306
Rwork0.228
R-free0.27990
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3voa
RMSD bond length0.012
RMSD bond angle1.591
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwarePHENIX (1.8_1069)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.0002.760
High resolution limit [Å]2.6067.7102.610
Rmerge0.0910.0330.610
Rmeas0.0380.710
Number of reflections162676412577
<I/σ(I)>11.7932.112.43
Completeness [%]98.499.496.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2931.0M Lithium chloride, 0.1M Sodium acetate, 30%(w/v) PEG6000, 10%(v/v) glycerol, 5mM GTPgammaS, VAPOR DIFFUSION, SITTING DROP, temperature 293K

222926