Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PHOTON FACTORY BEAMLINE AR-NW12A |
Synchrotron site | Photon Factory |
Beamline | AR-NW12A |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-06-02 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 62.070, 140.020, 86.260 |
Unit cell angles | 90.00, 97.66, 90.00 |
Refinement procedure
Resolution | 36.250 - 1.990 |
R-factor | 0.19304 |
Rwork | 0.191 |
R-free | 0.23593 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.132 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | MOLREP |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.070 |
High resolution limit [Å] | 1.990 | 2.000 |
Rmerge | 0.089 | 0.337 |
Number of reflections | 92430 | |
<I/σ(I)> | 4.05 | |
Completeness [%] | 93.0 | 91.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.8 | 293 | 20% PEG 8000, 0.6M magnesium chloride, 100mM Tris-HCl buffer, pH 5.8, VAPOR DIFFUSION, HANGING DROP, temperature 293K, temperature 293.0K |