3VQM
Small heat shock protein hsp14.0 of C-terminal deletion variant with C-terminal peptide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL41XU |
Synchrotron site | SPring-8 |
Beamline | BL41XU |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-04-20 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 1.0000 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 156.300, 161.900, 162.270 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.320 - 2.550 |
R-factor | 0.224 |
Rwork | 0.224 |
R-free | 0.27500 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3aab |
RMSD bond length | 0.006 |
RMSD bond angle | 0.900 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.590 |
High resolution limit [Å] | 2.550 | 2.550 |
Number of reflections | 65216 | |
<I/σ(I)> | 12 | 2.3 |
Completeness [%] | 97.2 | 92.6 |
Redundancy | 5 | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8 | 293 | 50 mM ammonium sulfate, 2.0% PEG8000, 15% glycerol, pH 8.0, VAPOR DIFFUSION, SITTING DROP, temperature 293K |