Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3VPD

LysX from Thermus thermophilus complexed with AMP-PNP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE AR-NE3A
Synchrotron sitePhoton Factory
BeamlineAR-NE3A
Temperature [K]95
Detector technologyCCD
Collection date2010-03-05
DetectorADSC QUANTUM 270
Wavelength(s)1
Spacegroup nameP 31 2 1
Unit cell lengths130.339, 130.339, 77.423
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution49.860 - 1.950
R-factor0.19845
Rwork0.196
R-free0.23777
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1uc8
RMSD bond length0.013
RMSD bond angle1.467
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0088)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.980
High resolution limit [Å]1.9501.950
Number of reflections55332
Completeness [%]99.799.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52932.5% PEG 400, 1.0M ammonium citrate, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon