Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3VHG

Recombinant thaumatin I at PH 8.0

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSPRING-8 BEAMLINE BL44XU
Synchrotron siteSPring-8
BeamlineBL44XU
Temperature [K]100
Detector technologyCCD
Collection date2010-11-12
DetectorADSC QUANTUM 210
Wavelength(s)0.9
Spacegroup nameP 21 21 21
Unit cell lengths43.636, 63.528, 71.771
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution10.000 - 1.000
R-factor0.1109
R-free0.15510
Structure solution methodAB INITIO
Starting model (for MR)3vhf
RMSD bond length0.015
RMSD bond angle0.031
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareSHELX
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.020
High resolution limit [Å]1.0001.000
Rmerge0.0440.371
Number of reflections107219
<I/σ(I)>46.74863.115
Completeness [%]98.885.7
Redundancy4.72.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP829350mM Tris-HCl buffer, 15% PEG3350, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon