3V6O
Leptin Receptor-antibody complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2009-04-05 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.9796 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 89.814, 118.829, 171.281 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.000 - 1.950 |
R-factor | 0.1735 |
Rwork | 0.171 |
R-free | 0.21350 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.023 |
RMSD bond angle | 1.840 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.000 | 2.000 |
High resolution limit [Å] | 1.950 | 1.950 |
Rmerge | 0.074 | 0.556 |
Number of reflections | 127050 | |
<I/σ(I)> | 15.9 | 3.8 |
Completeness [%] | 99.9 | 99.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 4.6 | 281 | sodium acetate, PEG-4000, pH 4.6, vapor diffusion, temperature 281K |