Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2007-02-23 |
Detector | KODAK |
Wavelength(s) | 1.07 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 84.307, 84.307, 117.219 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.892 - 3.501 |
R-factor | 0.3066 |
Rwork | 0.305 |
R-free | 0.34140 |
Structure solution method | SIRAS |
RMSD bond length | 0.012 |
RMSD bond angle | 2.582 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SHARP |
Refinement software | PHENIX ((phenix.refine: 1.6.1_357)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 40.000 |
High resolution limit [Å] | 3.500 |
Number of reflections | 5700 |
Completeness [%] | 98.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 298 | 100 mM MgSO4, 6.8 M NH4NO3, 100 mM Tris buffer, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |