3UP7
Aurora A in complex with YL1-038-09
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 93 |
Detector technology | CCD |
Collection date | 2010-06-02 |
Detector | RIGAKU SATURN 944+ |
Wavelength(s) | 1.54178 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 82.580, 82.580, 172.360 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 19.610 - 3.050 |
R-factor | 0.233 |
Rwork | 0.233 |
R-free | 0.29200 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3fdn |
RMSD bond length | 0.011 |
RMSD bond angle | 1.700 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | CNS (1.3) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 3.100 |
High resolution limit [Å] | 3.050 | 3.050 |
Rmerge | 0.068 | 0.371 |
Number of reflections | 7101 | |
<I/σ(I)> | 31.67 | 4.7 |
Completeness [%] | 99.3 | 100 |
Redundancy | 4.9 | 5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 10 mg/mL AURORA A protein, 1 mM YL1-038-09, 10 % (v/v) PEG 3350, 25 mM phosphate(Na/K pH 7.4), 100 mM sodium tartrate pH 7.0 VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 291K |