3UHZ
HBI (T72A) deoxy
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 2001-08-08 |
Detector | RIGAKU RAXIS IIC |
Wavelength(s) | 1.5418 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 91.990, 44.400, 144.130 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 33.220 - 2.000 |
R-factor | 0.181 |
Rwork | 0.181 |
R-free | 0.21400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4sdh |
RMSD bond length | 0.005 |
RMSD bond angle | 1.200 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | CNS |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.070 |
High resolution limit [Å] | 1.800 | 1.800 |
Rmerge | 0.081 | 0.307 |
Number of reflections | 18133 | |
<I/σ(I)> | 11.6 | 3.3 |
Completeness [%] | 87.7 | 88.7 |
Redundancy | 2.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | SMALL TUBES | 8.5 | 298 | 1.5-2.5 M phosphate, pH 8.50, SMALL TUBES, temperature 298K |