3UHQ
HBI (L36A) deoxy
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 298 |
| Detector technology | IMAGE PLATE |
| Collection date | 2005-02-07 |
| Detector | MAR scanner 345 mm plate |
| Wavelength(s) | 1.5418 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 91.760, 44.360, 143.820 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 38.680 - 1.950 |
| R-factor | 0.164 |
| Rwork | 0.164 |
| R-free | 0.18600 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4sdh |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.200 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 40.000 | 2.020 |
| High resolution limit [Å] | 1.950 | 1.950 |
| Rmerge | 0.087 | 0.280 |
| Number of reflections | 21878 | |
| <I/σ(I)> | 21.1 | 10.4 |
| Completeness [%] | 99.3 | 100 |
| Redundancy | 6.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | SMALL TUBES | 8.5 | 298 | 1.5-2.5 M phosphate, pH 8.50, SMALL TUBES, temperature 298K |