3U3Y
Mouse TREX1 D200H mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Detector technology | CCD |
Collection date | 2008-10-06 |
Detector | RIGAKU SATURN 92 |
Wavelength(s) | 1.54 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 65.066, 57.861, 68.227 |
Unit cell angles | 90.00, 108.11, 90.00 |
Refinement procedure
Resolution | 22.724 - 2.280 |
R-factor | 0.2162 |
Rwork | 0.213 |
R-free | 0.27530 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.096 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.7.1_743)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 40.000 |
High resolution limit [Å] | 2.280 |
Rmerge | 0.072 |
Number of reflections | 21089 |
<I/σ(I)> | 8.8 |
Redundancy | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 6 | 298 | 16% PEG 4000, 0.1 M MES pH 6.0, 2% 1,4-butanediol, VAPOR DIFFUSION, temperature 298K |