3TMV

X-Ray Radiation Damage to HEWL Crystals soaked in 100mM Sodium Nitrate (Dose=0.12MGy)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCHESS BEAMLINE A1
Synchrotron siteCHESS
BeamlineA1
Temperature [K]295
Detector technologyCCD
DetectorADSC QUANTUM 4
Wavelength(s)1.241
Spacegroup nameP 43 21 2
Unit cell lengths79.876, 79.876, 38.736
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.720 - 1.900
R-factor0.15514
Rwork0.152
R-free0.21913
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.027
RMSD bond angle1.969
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareBUSTER
Refinement softwareREFMAC (5.5.0110)
Data quality characteristics
 Overall
Low resolution limit [Å]56.480
High resolution limit [Å]1.900
Number of reflections10377
Completeness [%]100.0
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1

223532

PDB entries from 2024-08-07