3T8H
Thermolysin In Complex With UBTLN29
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.2 |
| Synchrotron site | BESSY |
| Beamline | 14.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2010-06-25 |
| Detector | RAYONIX MX-225 |
| Wavelength(s) | 0.91841 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 92.800, 92.800, 130.100 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 40.184 - 1.450 |
| R-factor | 0.1242 |
| Rwork | 0.123 |
| R-free | 0.15300 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 8tln |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.047 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX ((phenix.refine: 1.7_650)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.480 |
| High resolution limit [Å] | 1.450 | 1.450 |
| Number of reflections | 58688 | |
| <I/σ(I)> | 30 | 4.6 |
| Completeness [%] | 99.5 | 99.1 |
| Redundancy | 5.8 | 5.7 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291 | 50 mM Tris, 1.9 M cesium chloride, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |