3T8F
Thermolysin In Complex With UBTLN34
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.2 |
Synchrotron site | BESSY |
Beamline | 14.2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2010-12-14 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 0.91841 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 92.400, 92.400, 131.200 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 30.349 - 1.440 |
R-factor | 0.1429 |
Rwork | 0.142 |
R-free | 0.15860 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 8tln |
RMSD bond length | 0.012 |
RMSD bond angle | 1.048 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((phenix.refine: 1.7_650)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.460 |
High resolution limit [Å] | 1.440 | 1.440 |
Number of reflections | 60157 | |
<I/σ(I)> | 22 | 5.4 |
Completeness [%] | 99.7 | 96.2 |
Redundancy | 5 | 4.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291 | 50 mM Tris, 1.9 M cesium chloride, 50% DMSO, pH 7.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |