Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3T7Q

Endothiapepsin in complex with an inhibitor based on the Gewald reaction

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]100
Detector technologyCCD
Collection date2009-08-15
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)1.000
Spacegroup nameP 1 21 1
Unit cell lengths45.410, 73.070, 52.840
Unit cell angles90.00, 109.71, 90.00
Refinement procedure
Resolution29.446 - 1.300
R-factor0.1625
Rwork0.162
R-free0.17450
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1oew
RMSD bond length0.005
RMSD bond angle1.069
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((phenix.refine: 1.7_650))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]40.0001.320
High resolution limit [Å]1.3001.300
Number of reflections78609
<I/σ(I)>20.92.2
Completeness [%]100.0100
Redundancy3.32.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.62890.1 M NH4Ac, 0.1M acetate-buffer, 26% PEG4000, pH 4.6, VAPOR DIFFUSION, SITTING DROP, temperature 289K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon